Part 5 – Wastewater Drainage
5.7 Joints
Specification of joints shall be as follows:
- All pipes shall normally have flexible joints of an approved type, such as RRJ.
- Steel pipes shall be flexibly jointed (gibault or approved rubber ring).
- Solvent cement joints shall only be used for PVC if specifically required by Council.
- Joints shall be provided adjacent to manholes. Proprietary connections may be used in the case of PVC pipelines.
- All joints are to be designed and constructed to remain fully watertight for the design life (100 years) of the pipe network.